Andros CMS

Cabinet management/control module with lamp control on Power line, that can be remotely or locally configured. Configuration up to 1.022 Syra per cabinet. Visualization of the lamp devices, SYRA, on display.

request a quote

  • It checks the power supply and the detection status in case of:  network absence, low and/or insufficient battery
  • Events’ check at cabinet level with detection of: inputs starting up/disconnection, tension presence/absence, connected modules anomaly
  • and faulty lamps
  • Sending of starting up, switching off and flux reduction commands to every lighting point
  • Output command relays or open collector outputs
  • Lamp events check with detection of: short-circuit lamp, interrupted lamp, current absence, faulty capacitor, flashing lamp, interrupted ballast
  • Emergency calls starting up for the main events
  • Command cycles program ON/OFF/Dimming based upon astronomic clock  and 32 weekly timers
  • Management of 1.022 lamps command modules (SYRA) over 15 groups
Specifications:
  • Working voltage 15 V~
  • Absorbed current during stand-by phase )70 mA @ 10,4V~
  • Digital inputs N. 16 opto-insulated
  • Open collector outputs – N°6 12Vcc 20mA
  • Outputs relays NA-NC N°1 230V~ 3A ac1c
  • Connection output for ANDROS PLS-12Vac +/-10% 3VA
  • Connection output for PAROS-12Vdc (250mA Max)
  • Electrical Insulation Class-II
  • Protection degree-IP20
  • Dimension-9 DIN Modules
  • Weight-650gr

Get the full datasheet here

See all FAQS below:

Faqs (Supervision System)
Faqs (Common)
Faqs (Cabinet Remote Control)